I presume all of that was evaluated when we built this facility 6yrs ago. We hired an EH&S firm for the first 2 (if not 3) years to help us meet all requirements. Grounding of new unopened drums and use of spill containment platforms for
storage of said drums were not part of the set-up. Since then, we added grounding. However, the actual requirements for grounding remain unclear. Now we’re looking at the spill platform idea. I think is a good idea, but need to figure out the requirements.
Thank you,
Yaritza Brinker
260.827.5402
From: ACS Division of Chemical Health and Safety <DCHAS-L**At_Symbol_Here**PRINCETON.EDU>
On Behalf Of Zack Mansdorf
Sent: Tuesday, April 23, 2019 3:09 PM
To: DCHAS-L**At_Symbol_Here**PRINCETON.EDU
Subject: Re: [DCHAS-L] solvent drums
** External Email **
Yaritza:
This is actually much more complicated than a simple rule. It is multifactorial and highly dependent on a risk assessment..
Is this a lot of drums or just a few?
Do you have floor drains?
Do you have floor containment (sloped to contain any spill with raised sills and no drains)?
Are the solvents compatible with wood or should you be using plastic pallets?
Are the solvents compatible with the flooring?
Are the solvents highly volatile and with low OELs?
Are the solvents highly flammable?
Do you have adequate sprinklers (and the right type) for the storage in case of fire?
Do you have ventilation in the storage area?
Do you have spill response equipment?
I could go on for a long time but will stop here. Get the advice of a good IH or safety person that you respect.
In most locations, the local zoning board or the local fire marshal will approve this type of storage and use. Was that done?
Good luck
Zack
S.Z. Mansdorf, PhD, CIH, CSP, QEP
Consultant in EHS and Sustainability
7184 Via Palomar
Boca Raton, FL 33433
561-212-7288
From: ACS Division of Chemical Health and Safety <DCHAS-L**At_Symbol_Here**PRINCETON.EDU>
On Behalf Of Yaritza Brinker
Sent: Tuesday, April 23, 2019 2:15 PM
To: DCHAS-L**At_Symbol_Here**PRINCETON.EDU
Subject: [DCHAS-L] solvent drums
Hello,
Our new unopened drums are stored on a wood palette until they are needed. A colleague recently suggested that new unopened drums should be stored on a spill containment platform instead of the palette. However, I have visited plenty of
facilities where new unopened drums are stored directly on the concrete floor. Is there a rule on this? Where can I find it?
Also, there’s some debate as to whether or not new unopened drums need to be grounded while in storage?
Thanks,
Yaritza Brinker
Electronic Transmission Confidentiality Notice
The information contained in this electronic transmission is private, confidential, the property of
the sender, and intended for the use of the recipient(s),
only. If you are not the addressee, any disclosure, copying, distribution or use of this information for any purpose is strictly
prohibited. If you have received this information in error, please notify the sender,
YBrinker**At_Symbol_Here**fele.com,
immediately by e-mail and then delete this message. Thank you.
[FE.EN.1]
--- For more information about the DCHAS-L e-mail list, contact the Divisional membership chair at
membership**At_Symbol_Here**dchas.org Follow us on Twitter **At_Symbol_Here**acsdchas
--- For more information about the DCHAS-L e-mail list, contact the Divisional membership chair at
membership**At_Symbol_Here**dchas.org Follow us on Twitter **At_Symbol_Here**acsdchas
Previous post | Top of Page | Next post