If azides/peroxide formers are regularly manipulated for the peptide and carbohydrates syntheses in a lab, a rotavapor inside a chemical fume hood will provide additional safety. Also, a roptavapor inside a chemical fume hood will reduce the odor problem during thiol chemical manipulations. For regular chemical manipulations, rotavapor on a benchtop corner serves the purpose very well in syntheses labs.

 

Tilak

 

 

Tilak Chandra, Ph.D.

Chemical Safety Specialist

UW-Madison

tchandra**At_Symbol_Here**fpm.wisc.edu

 

 

 

From: DCHAS-L Discussion List [mailto:dchas-l**At_Symbol_Here**med.cornell.edu] On Behalf Of ILPI Support
Sent: Tuesday, September 22, 2015 11:22 AM
To: DCHAS-L**At_Symbol_Here**MED.CORNELL.EDU
Subject: Re: [DCHAS-L] Rotovaps and ventilation

 

Unless you're in a magical world where hood space is more widely available than PAC money, I'd have to say that safety/ventilation etc. is way down the list for most PI's.  In many all of the labs I've worked in, hood space is too valuable (i.e.. scarce) to take up with a rotovap, and a rotavap setup is so bulky and difficult to move it would impractical to move it into a hood if you had something really nasty.  In that case, we'd instead remove the solvent with a vacuum/Schlenk line that is already in the hood.

 

That said, one should always set up proper traps, pumps, venting and safety shields for rotavaps used on an open bench top.  I assume various places have SOP's for that. 

 

Rob Toreki

 

 ======================================================

Safety Emporium - Lab & Safety Supplies featuring brand names

you know and trust.  Visit us at http://www.SafetyEmporium.com

esales**At_Symbol_Here**safetyemporium.com  or toll-free: (866) 326-5412

Fax: (856) 553-6154, PO Box 1003, Blackwood, NJ 08012

 

 

On Sep 22, 2015, at 9:16 AM, "Stuart, Ralph" <Ralph.Stuart**At_Symbol_Here**keene.edu> wrote:



Random question for the morning:
What factors determine whether a rotovap should be used in a hood or not?

Thanks for any feedback on this.

- Ralph

Ralph Stuart, CIH, CCHO
Chemical Hygiene Officer
Keene State College

ralph.stuart**At_Symbol_Here**keene.edu

 

Previous post   |  Top of Page   |   Next post



The content of this page reflects the personal opinion(s) of the author(s) only, not the American Chemical Society, ILPI, Safety Emporium, or any other party. Use of any information on this page is at the reader's own risk. Unauthorized reproduction of these materials is prohibited. Send questions/comments about the archive to secretary@dchas.org.
The maintenance and hosting of the DCHAS-L archive is provided through the generous support of Safety Emporium.