From: Frank Coppo <Frank.T.Coppo**At_Symbol_Here**GSK.COM>
Subject: Re: [DCHAS-L] Re; amorphous silica
Date: June 28, 2012 9:48:52 AM EDT
Reply-To: DCHAS-L <DCHAS-L**At_Symbol_Here**MED.CORNELL.EDU>
Message-ID: <1D1C210A-2C88-4374-8988-9BB698E5FA80**At_Symbol_Here**DCHAS.ORG>

Folks -

I'd have to believe this would be considered RCRA regulated hazardous waste (it is here in PA), not appropriate for the trash (municipal waste), regardless of mass/volume.

Best regards, Frank


-----Original Message-----
From: DCHAS-L Discussion List [mailto:dchas-l**At_Symbol_Here**MED.CORNELL.EDU] On Behalf Of Secretary, ACS Division of Chemical Health and Safety
Sent: Wednesday, June 27, 2012 1:27 PM
To: DCHAS-L**At_Symbol_Here**MED.CORNELL.EDU
Subject: [DCHAS-L] Re; amorphous silica

From: Rita Kay Calhoun
Subject: RE: [DCHAS-L] Toxic dust handling
Date: June 27, 2012 12:10:28 PM EDT

What about disposal of silica gel? If the column is stripped of sample, can it be sealed in a bag and disposed of in the trash? I'm talking about small amounts, certainly less than 2-300 grams.

Kay

===
From: Keith Rickabaugh
Subject: amorphous silica correction - - - RE: [DCHAS-L] Toxic dust handling
Date: June 27, 2012 12:29:44 PM EDT

I disagree with amorphous silica being cited as a "nuisance dust".

Independent of any toxicity issues, amorphous silica is a regulated substance by OSHA as per 29 CFR 1910.1000 (see table z-3). However, I believe that this is rarely (if ever) enforced. Even though there are reasonable arguments that this OSHA PEL reference value is outdated and may not be relevant - it is still the law.

The OSHA PEL is a calculated value that is based off of the percent of amorphous silica material in the particulate: 80 mg / % amorphous silica.

Many people are confused by this formula as they incorrectly think that the % silica in the formula is for crystalline silica.

If working with 100% amorphous silica, the PEL would 0.8 mg per cubic meter.

This is the one and only instance that I have noted that the OSHA PEL is actually lower than ACGIH TLV or NIOSH REL values.

See links below if interested in learning more:

http://www.osha.gov/pls/oshaweb/owadisp.show_document?p_table=STANDARDS&p_id&trade;94

http://www.osha.gov/pls/oshaweb/owadisp.show_document?p_table=INTERPRETATIONS&p_id=25740


Keith Rickabaugh

Technical Director, Materials & Analytical Services

RJ Lee Group
www.rjlg.com

724.325.1776 Office
724.387.1841 Direct
724.309.6732 Mobile
724.733.1799 Fax

350 Hochberg Road | Monroeville, PA 15146

Please let us know if we've met your expectations on your project by visiting our Customer Survey.

===

Previous post   |  Top of Page   |   Next post



The content of this page reflects the personal opinion(s) of the author(s) only, not the American Chemical Society, ILPI, Safety Emporium, or any other party. Use of any information on this page is at the reader's own risk. Unauthorized reproduction of these materials is prohibited. Send questions/comments about the archive to secretary@dchas.org.
The maintenance and hosting of the DCHAS-L archive is provided through the generous support of Safety Emporium.