I agree with Rob Toreki,
 
This is a senseless regulation that would do much more harm than good,&nb sp;and presents a slip-and-fall hazard full time, not just whe n the emergency shower is in use.
 
I also agree with how dilute most chemical splashes would be by the time yo u dilute them with 15 minutes **At_Symbol_Here** 20 gallons/minute = 300 gallons of water.
 
Alan
Alan H. Hall, M.D.
 


Date: Thu, 28 Oct 2010 14:55:20 -0400
From: info**At_Symbol_Here**ILPI.COM
Subject: Re: [DCHAS-L] Lab safety showers
To: DCHAS-L**At_Symbol_Here**LIST.UVM.EDU

Wow, thanks for sharing.  That one is a poster child for Bad Regulations.

1. Let's say the berm encompasses a 4' x 4' area around the shower. &n bsp;That's 16 square feet, one inch high, for a volume of 1.33 cubic feet = 10 gallons.  Under ANSI Z358, showers must put out at lea st 20 gallons per minute.  And that shower is likely to flow for 5 , if not 15 minutes.  So the berm is essentially useless.

Now, if the reg is calling for a berm that say, stretches across a n entire hallway or doorway - heck, or just around the drain itself, th at might work by flooding the rest of the building, as all it does is mak e the floor drain non-functional.  Plugging the floor drain permanen tly is an easier solution.

2. The amount of hazardous material on a victim is going to be so exce edingly small and so diluted in the drains that it boggles the mind.   ;Seriously - you get what, 10 mL of concentrated acid on you and that w ashes down the drain with 100 gallons of water?   Yeesh.  And if the stuff was so nasty toxic that it is a hazard even that dilue, thi s city review department thinks it's better to spread the hazmat all over t he building and down a couple floors onto various objects and people than i t is to send it down the drain.

3. When you're blinded by something and trying to find a shower on foo t or on a wheelchair, even that 1" sloped bump is a barrier.  And no doubt a trip hazard the rest of time no matter how well it's marked with floor tape.

Rob Toreki

  ================== ========================= ===========
Safety Emporium - Lab & Safety Supplies featuring brand names
you know and trust.  Visit us at http://www.SafetyEmporium.com
esales**At_Symbol_Here**safetyemporium.com  or toll-free: (866) 326-5412
Fax: (856) 553-6154, PO Box 1003, Blackwood, NJ 08012


On Oct 28, 2010, at 2:31 PM, Betsy Shelton wrote:

I am currently involved in construction of two new laboratories and was instructed by the city commercial building review department to in clude a 1" high curb around the shower area to keep hazmat from entering th e floor drain in the event of a spill.  Also, the curb has to be s loped on both sides to allow accessibility.

--
Best regards,
Betsy Shelton
512.636.1905
retrosynthesis**At_Symbol_Here**gmail.com


Previous post   |  Top of Page   |   Next post



The content of this page reflects the personal opinion(s) of the author(s) only, not the American Chemical Society, ILPI, Safety Emporium, or any other party. Use of any information on this page is at the reader's own risk. Unauthorized reproduction of these materials is prohibited. Send questions/comments about the archive to secretary@dchas.org.