Hi all If you remember I recently got a job and all is going great. I'm trying to reorganize the lab being many of us are new. So far I have isolated bulk/strong acids and bases in their own cabinets. We also have many acids and bases that we use day to day and keep them out in the open. Most of them are relatively weak, but some are very strong. In the past, the company kept things at workstations. I (and my boss) didn't think that was a very good idea. To much clutter, to many expired/unstandardized chemicals going un noticed and to many duplicates. We decided on one bottle of everything, no more, but perhaps less (zero) if it isn't used often and easy to make. To my question, these small (less then 1L) caustics need to be left out, eventually I'll push for a proper storage cabinet for non-bulk items, but until then they are on a shelf. I decided to store the acids on the bottom shelf of the left bay, and the bases on the bottom shelf of the right bay with neutral solutions on the top shelves and in the middle bay. My philosophy being that if the bottle falls, it doesn't fall far. If it leaks, it leaks on empty bench space, and if it does spread to surrounding chemicals, it is either a like chemical or a neutral chemical. All acids and bases are at least 4ft apart separated by 2 shelf walls. I don't have much to work with, I know it could be a lot safer, but if anyone can think of any ideas with what I described I would like to hear them. -Andrew On Thu, Aug 13, 2009 at 9:15 AM, Nail, Johnwrote: > Let me see if I have this straight - > A researcher uses an extinguisher to put out a lab fire. > An OSHA investigator cites the institution for lack of documented extingu isher training, despite the obvious fact that the researcher was able to su ccessfully put out the fire. > The local FD begins to remove extinguishers from the labs. > > My suggestion about putting out trash can fires was in regards to the OSH A training issue. BTW- when I was at another university, all Chemistry depa rtment personnel were required to use an extinguisher to put out an oil fir e during the annual safety training. > > As a trained firefighter, you can be as angry as you want to over the ide a that 'untrained' (unwashed?) people dare to put out fires. As a trained c hemist who has worked extensively with pyrophoric materials, I am angry ove r your attitude that lab workers should not be allowed to extinguish small lab fires. As an educator, I would not let students use flammable liquids i n a lab unless an extinguisher was available for me to use in any incidents . > > This idea of 'remove safety equipment because lab personnel are too stupi d/untrained/untrustworthy to use it properly is condescending, and frankly, leads to an attitude that gets people killed. > > What EVERYONE needs to recognize is that there is a significant differenc e between a small hood fire and a major building fire. Whomever first disco vers the small hood fire should put it out if they can do so safely, and ye s, those of us who have handled dangerous materials, know a thing or two ab out working safely. And, no, I would try to fight a large fire. Yes, someon e has to use their judgment when assessing the situation. > > Whether the issue is extinguishers in lab areas or freshman chemistry stu dents wearing gloves, the key question is 'do we teach how to assess risks and use the PPE and safety equipment that is appropriate to that risk or do we give students a mindless set of rules?' > > In regards to the 'this is how its done in industry' argument, yes, I hav e been in industry. Industry and academia are two very different cultures. People in industry have different motivations than do people in academia. I ndustry and academia are not valid comparisons. > > It's easier to create rules than to think. > > John Nail > Professor of Chemistry > Oklahoma City University > > -----Original Message----- > From: DCHAS-L Discussion List [mailto:DCHAS-L**At_Symbol_Here**LIST.UVM.EDU] On Behalf Of Andrew Gross > Sent: Wednesday, August 12, 2009 5:03 PM > To: DCHAS-L**At_Symbol_Here**LIST.UVM.EDU > Subject: Re: [DCHAS-L] Extinguishers > > I can not agree more. =A0I wrote almost an identical email, but I > decided to wait 24 hours to let my anger at the suggestion die down to > make sure I wasn't coming on strong. =A0Here is what I wrote yesterday: > > I have to strongly disagree with your live burn training. =A0As a > firefighter, I am trained to recognize and understand the difference > between a Class A through D fire. =A0What you are describing would be a > Class A fire, which for cost reasons, would most likely be put out > with a Class A extinguisher/Water Can. =A0The students would know how to > put out a class A combustible fire sure, but that is the furthest > thing from a threat in a laboratory. > > In a lab you have to worry about the class B (oil based) and class D > (misc/exotic) fires. =A0Even if the student is educated in which > extinguisher to grab, attacking a Class B or D fire in the same tactic > that you would attack a class A fire would most definitely be > catastrophic, only to encourage the spread of the involved material. > > What students need to be taught is fire prevention and the basics and > have them constantly reinforced. =A0First, never panic, stop drop and > roll in fire, know your exits and stay low during evacuation as well > as use of a fire blanket. =A0We don't need heros in the laboratory, we > need prudent, safe workers. =A0Leave the hero game to trained > professionals or someone will get hurt. > > Perhaps the FD removed the cans for a reason. =A0A class A extinguisher > has no place in a lab and you are better off with nothing. =A0You need a > combination of A/B/C and B/C cans as well as the proper D can for > whatever is in the lab (ie, purple K for phosphorus) > > To the contrary, I like the "don't panic" training you laid out. =A0If > you would like more consultation on that feel free to ask. > > Sorry to knock your idea in public, but setting a garbage can on fire > and calling it training is just asking for a funeral when a chem fire > erupts and some dope thinks its the same attack. > > Drew > > On Wed, Aug 12, 2009 at 10:31 AM, List Moderator wrote: >> From: =A0 rj**At_Symbol_Here**strem.com >> Subject: =A0 =A0 =A0 =A0RE: [DCHAS-L] Extinguishers >> Date: =A0 August 12, 2009 10:03:56 AM EDT >> >> There are a lot of different regulations that we all have to abide by, >> and they can be very confusing as to which ones to follow. Being a >> firefighter, I can tell you that Debbie is correct when it comes to Fire >> Code. =A0Your local/state fire marshal's office decides the regulations, >> but that does not mean if you have fire extinguishers present to ignore >> OSHA regulations. >> >>> From a firefighter's standpoint, when it comes to fires in a lab, we >> >> never like to see anyone try to extinguish a fire. The reasoning for >> this is, the student/employee does not have on the correct PPE on to try >> to fight a fire. Working with chemicals we know that a fire can get out >> of control very quickly, and we don't want anyone getting caught in a >> situation like that without firefighter experience, proper training, or >> correct PPE. >> >> After that being said fire extinguishers still belong in the lab. The >> main propose of a fire extinguisher is for defensive use. Meaning, if >> there was a fire that blocked the exits of a room, a fire extinguisher >> should be available to use to assure the safe exit of everyone from the >> room/building. =A0So, I completely disagree with the removal of the fire >> extinguishers from the facility, your lab needs to have training at >> least once a year, and ask the fire department for help with the >> training. Fire extinguishers are a life safety tool and they should be >> present! >> >> You should also check with your local fire department to see if the >> community has adopted National Fire Protection Association (NFPA) >> standards. If they have adopted them then you would want to get NFPA 10 >> Standard for Portable Fire Extinguishers. >> >> Best regards, >> >> R.J. Wolcik >> >> Confidentiality Notice: This e-mail transmission may contain >> confidential or legally privileged information that is intended only for >> the individual or entity named in the e-mail address. If you are not the >> intended recipient, you are hereby notified that any disclosure, >> copying, distribution, or reliance upon the contents of this e-mail is >> strictly prohibited. If you have received this e-mail transmission in >> error, please reply to the sender, so that Strem Chemicals Inc. can >> arrange for proper delivery, and then please delete the message from >> your Inbox. Thank you. >> >
Previous post | Top of Page | Next post