Per Hazard Communication standard; SDS have to report  1% for hazardous ingredients and 0.1% for carcinogens.  

V/r, 
Mike

Michael N. Cooper MS, MPH, CIH
Certified Industrial Hygienist
Radiation Protection Technologist
mcooperconsulting**At_Symbol_Here**yahoo.com


Adjunct Professor
Department of Community and Environmental Health
School of Allied Health Sciences,
College of Health Sciences 
Boise State University 
michaelcooper961**At_Symbol_Here**boisestate.edu
(408) 313-2127


On Feb 10, 2022, at 09:13, Monique Wilhelm <mwilhelm**At_Symbol_Here**umich.edu> wrote:

Hi Everyone,

QUESTION:  Is the toxic hazard and pictogram required on these labels?  

I thought I read somewhere that a label for a mixture does not have to include the hazard of any component less than 1% but cannot easily find it right now.  I know carcinogens designations occur at a much lower concentration, 0.001%.  So, is the 1% rule true?  Does anyone know of this guideline?

My institution uses ChemWatch Gold FFX for SDS and labeling info.  Being a biochemist who always made her own solutions, when I looked up TBE info, I looked up each component.  Boric acid is listed as a reproductive poison health hazard on its SDS.  But, the researcher just looked up TBE buffer and it was listed as non-hazardous.  The boric acid is at 0.5% when at 1x concentration, but is often made at 10x concentration and later diluted down.  Is it still considered hazardous at these concentrations and require the toxic hazard and pictogram on these labels?

Thank you,
_________________________________________________________
Monique Wilhelm
Lab Manager
CAS, Department of Natural Sciences | The University of Michigan-Flint
303 E. Kearsley St | Room 572 MSB | Flint, MI | 48502-1950
--- For more information about the DCHAS-L e-mail list, contact the Divisional membership chair at membership**At_Symbol_Here**dchas.org Follow us on Twitter **At_Symbol_Here**acsdchas

Previous post   |  Top of Page   |   Next post



The content of this page reflects the personal opinion(s) of the author(s) only, not the American Chemical Society, ILPI, Safety Emporium, or any other party. Use of any information on this page is at the reader's own risk. Unauthorized reproduction of these materials is prohibited. Send questions/comments about the archive to secretary@dchas.org.
The maintenance and hosting of the DCHAS-L archive is provided through the generous support of Safety Emporium.