From: Dr Bob <drbob**At_Symbol_Here**FLOWSCIENCES.COM>
Subject: Re: [DCHAS-L] Quick Question
Date: Sat, 4 Sep 2021 13:17:59 +0000
Reply-To: ACS Division of Chemical Health and Safety <DCHAS-L**At_Symbol_Here**Princeton.EDU>
Message-ID: BN8PR07MB6340EC36E529B78C324E8428D9D09**At_Symbol_Here**BN8PR07MB6340.namprd07.prod.outlook.com
In-Reply-To <63b1228da69c41fca1ae0d659afac555**At_Symbol_Here**umhb.edu>


Make it easier for us; what's the compound?



Sent from my Samsung Galaxy , an AT&T LTE smartphone



-------- Original message --------
From: "Murphy, Dr. Ruth Ann" <rmurphy**At_Symbol_Here**UMHB.EDU>
Date: 9/3/21 4:03 PM (GMT-05:00)
To: DCHAS-L**At_Symbol_Here**Princeton.EDU
Subject: [DCHAS-L] Quick Question

Greetings and Happy Labor Day Weekend,

 

Should a compound (ionic liquid) with the following SDS statement be safe to use in small amounts, e.g., 5 g, in a fume hood, without a respirator?  We would just be making solutions and running them through a viscometer. Students are enthusiastic about this project, but I am cautious.   The highlighted info in the SDS statement below about a risk assessment seems a bit cryptic.

 

SECTION 8: Exposure controls/personal protection
8.1 Control parameters
Components with workplace control parameters
Contains no substances with occupational exposure limit values.
8.2 Exposure controls
Appropriate engineering controls
Handle in accordance with good industrial hygiene and safety practice. Wash hands
before breaks and at the end of workday.
Personal protective equipment
Eye/face protection
Safety glasses with side-shields conforming to EN166 Use equipment for eye
protection tested and approved under appropriate government standards such as
NIOSH (US) or EN 166(EU).
Skin protection
Handle with gloves. Gloves must be inspected prior to use. Use proper glove
removal technique (without touching glove's outer surface) to avoid skin contact
with this product. Dispose of contaminated gloves after use in accordance with
applicable laws and good laboratory practices. Wash and dry hands.
Body Protection
Impervious clothing, The type of protective equipment must be selected according
to the concentration and amount of the dangerous substance at the specific
workplace.
Respiratory protection
Where risk assessment shows air-purifying respirators are appropriate use a full-
face respirator with multi-purpose combination (US) or type ABEK (EN 14387)
respirator cartridges as a backup to engineering controls. If the respirator is the sole
means of protection, use a full-face supplied air respirator. Use respirators and
components tested and approved under appropriate government standards such as
NIOSH (US) or CEN (EU).

 

Thank you!

 

Ruth Ann

 

Ruth Ann Cook Murphy, Ph.D.

Professor of Chemistry

Chairperson, Department of Chemistry, Environmental Science and Geology

Co-Chairperson, Health Professions Advisory Committee

Amy LeVesconte Professorship of Chemistry

JAMP Faculty Director

University of Mary Hardin-Baylor

900 College Street

Belton, TX  76513-2599

Phone 254.295.4542

Accepting Christ is life's greatest decision; following Christ is life's greatest adventure.

 

 

 

 

 

 

--- For more information about the DCHAS-L e-mail list, contact the Divisional membership chair at membership**At_Symbol_Here**dchas.org Follow us on Twitter **At_Symbol_Here**acsdchas

Previous post   |  Top of Page   |   Next post



The content of this page reflects the personal opinion(s) of the author(s) only, not the American Chemical Society, ILPI, Safety Emporium, or any other party. Use of any information on this page is at the reader's own risk. Unauthorized reproduction of these materials is prohibited. Send questions/comments about the archive to secretary@dchas.org.