Also- Chapter 1 of Guidelines for Laboratory Design: Health, Safety, and Environmental Considerations, 4th Edition https://media.wiley.com/product_data/excerpt/24/04705055/0470505524-374.pdf
Page 8:
"The definition of net area as established by the Building
Owners Management Association (BOMA) is "the total
floor area within the walls of a space. Measure length
and width from centerline-to centerline of walls (except
the exterior walls)" (BOMA Z65.1, 1996). "Net assignable
area does not include area used for public corridors,
structural elements, exterior walls, mechanical
equipment rooms, or duct and pipe shafts, toilets, and
other building support facilities. Those elements are
accounted for in building gross area " (BOMA Z65.3,
2009)."
Thank you,
Yaritza Brinker
260.827.5402
From: Yaritza Brinker
Sent: Thursday, August 15, 2019 1:57 PM
To: ACS Division of Chemical Health and Safety <DCHAS-L**At_Symbol_Here**PRINCETON..EDU>
Subject: RE: [DCHAS-L] [EXT] Re: [DCHAS-L] Space Reuirements for Undergraduate Chemistry Laboratories
The Occupant Load Factor is used to calculate the minimum fire safety requirements for the building/portion of the building NOT to calculate the space allotted per student in a particular room.
See NFPA's video regarding this topic https://youtu.be/FbiVenRL5JQ
See also NFPA 1: Fire Code requirements for laboratories at college and universities, #FireCodefridays https://community.nfpa.org/community/nfpa-today/blog/2018/11/16/nfpa-1-fire-code-requirements-for-laboratories-at-college-and-universities-firecodefridays/
Thank you,
Yaritza Brinker
260.827.5402
From: ACS Division of Chemical Health and Safety <DCHAS-L**At_Symbol_Here**PRINCETON.EDU>
On Behalf Of Jack Williams
Sent: Thursday, August 15, 2019 12:06 PM
To: DCHAS-L**At_Symbol_Here**PRINCETON.EDU
Subject: Re: [DCHAS-L] [EXT] Re: [DCHAS-L] Space Reuirements for Undergraduate Chemistry Laboratories
** External Email **
We probably face some of the same problems as many colleges and universities in terms of the number of students
that can safely occupy a general chemistry laboratory.
Information from NFPA sets 50 sq. ft. "net" per occupant. I am thinking that "net" includes benchtop working space and excludes glassware and chemical storage cabinets.
Would anyone be able to tell me if my interpretation is correct?
Thanks for any help with this.
Jack
Jack D. Williams, Ph.D.
Professor of Chemistry
Department of Chemistry and Biochemistry
Mercyhurst University
Erie PA 16546
Phone: (814) 825-26211
Office: 311 Zurn
Research Lab: 307 Zurn
--- For more information about the DCHAS-L e-mail list, contact the Divisional membership chair at membership**At_Symbol_Here**dchas.org Follow us on Twitter **At_Symbol_Here**acsdchas
The information
contained in this electronic transmission is private, confidential, the property of the sender, and intended for the use of the recipient(s),
only.. If you are not the addressee, any disclosure, copying, distribution or use of this information for any purpose is strictly
prohibited. If you have received this information in error, please notify the sender,
YBrinker**At_Symbol_Here**fele.com, immediately by e-mail and then delete this message. Thank you.
[FE.EN.1]
Previous post | Top of Page | Next post