Bettcha I know why they did that.  These are off the shelf welding snorkels and so they didn't have to do anything but install them.  Bettcha they never even asked what you actually did on that counter or needed.  Jaded and bitter old Monona


-----Original Message-----
From: Samuella Beth Sigmann <sigmannsb**At_Symbol_Here**APPSTATE.EDU>
To: DCHAS-L <DCHAS-L**At_Symbol_Here**PRINCETON.EDU>
Sent: Tue, Feb 26, 2019 1:51 pm
Subject: Re: [DCHAS-L] 4 more Re: [DCHAS-L] Regulations for Snorkels

Thanks, Ralph -

So they have put snorkels in the new Biosuite and in the new Organic Synthesis lab.  Not sure why or where they got into the plans as I was not as involved with those as the teaching labs.  I think they will serve fine in the Biosuite if the workers are trained in their use.  I was hoping that the ones in the Orgo lab  might serve a rotovap on the counter.

The project manager asked me today if there were any regulations for testing them because the lab supplier is only planning on testing the hoods.  I will pass all the info on to them!
S-

On 2/26/2019 10:35 AM, DCHAS Membership Chair wrote:
From: Ken Kretchman <kwkretch**At_Symbol_Here**ncsu.edu>
Subject: Re: [DCHAS-L] Regulations for Snorkels
Date: February 26, 2019 at 10:11:25 AM GMT-5

Sammye

First...like Harry said....

If you have snorkles (and it is often tough to enclose everything)  you would want to test the capture velocity at the point where the contaminant is released and with the snorkle in position.  (You might test with smoke as well). That will give you some idea of effectiveness...or lack often lack of as Harry indicates.. 

You can also test right at the face of the snorkle in the centerline and calculate the cfm.

The appropriate number to look for design cfm is something you should be able to find in the ACGIH Industrial Ventilation Manual.

This is a reference used for design purposes for local exhaust ventilation and a good reference to have on hand.

Your IH group probably has a copy.

thanks
Ken


Ken Kretchman, CIH, CSP   Director, Environmental Health and Safety
NC State University / Box 8007 / 2620 Wolf Village Way / Raleigh North Carolina 27695-8007
Email: Ken_Kretchman**At_Symbol_Here**ncsu.edu / Phone: (919).515.6860 / Fax: (919).515.6307
===

From: Monona Rossol <actsnyc**At_Symbol_Here**cs.com>
Subject: Re: [DCHAS-L] Regulations for Snorkels
Date: February 26, 2019 at 10:24:10 AM GMT-5

Sammye, See ACGIH manual: Remember, it's title -- "Industrial Ventilation: A Manual of Recommended Practice."  I use the 29th edition, 2016.  Don't use much earlier editions if possible.  Everything your peeps need is there, but the engineers you need are industrial ventilation designers and this is already their Bible.  If instead, your engineers start speaking in ASHRAE, they are not going to be able to do what you need.  The ASHRAE standards often reference the ACGIH Manual in footnotes, but it should, in fact, be the first source of standards for lab ventilation rather then a footnote.

For flexible ducts: read Chapter 6 with emphasis on 6.7.4 and see also 13.65 MOVABLE EXHAUST HOODS and VS 65 01.  The hood needs to be designed to the purpose (not some generic ASHRAE system).  For solvents there is a specific capture velocity within the small capture zone of a flexible duct exhaust which you can find in Chapter 6.  If you want to modify an existing system, remember, most were designed for welding so you'll need to check resistance of all components to solvents or whatever else you intend to suck.  And avoid those cockamamie off-the-shelf systems with all the knuckle joints which require air to make rapid changes in direction.  Those will work as soon as someone repeals the laws of physics.

The welding hood air-flow standard is 1500 f/m measured at the center of the hood's face.  But you need to look at your purpose which is not to move a heated particulate but a hot vapor that is in molecular form.  Your system can use a lower face velocity based on the size of the hood and the area it needs to function in.

Monona
===
From: "Ellen M. Sweet" <ems325**At_Symbol_Here**cornell.edu>
Subject: RE: [DCHAS-L] Regulations for Snorkels
Date: February 26, 2019 at 10:00:25 AM GMT-5

No, other than what Ralph and harry have said about the Industrial Ventilation Manual.

I have had some luck with manufacturer recommendations for specific equipment that is not a fume hood.

Ellen

===
From: "Aaron's Phone" <cycling1**At_Symbol_Here**verizon.net>
Subject: Re: [DCHAS-L] Regulations for Snorkels
Date: February 26, 2019 at 10:09:39 AM GMT-5

Hi all, I would also take a look at ANSI Z9.5.   It has good guidance that aligns well with ASHRAE.

Regards,
Aaron Chen, MPH, CIH, FAIHA

---
For more information about the DCHAS-L e-mail list, contact the Divisional membership chair at membership**At_Symbol_Here**dchas..org
Follow us on Twitter **At_Symbol_Here**acsdchas

--
******************************************************************************
We, the willing, led by the unknowing, are doing the impossible for the ungrateful. We have done so much, for so long, with so little, we are now qualified to do everything with nothing. Teresa Arnold paraphrased from Konstantin Josef Jire=C4=8Dek (1854 - 1918)
 
Samuella B. Sigmann, MS, NRCC-CHO
Senior Lecturer/Safety Committee Chair/Director of Stockroom
Chemistry
Appalachian State University
525 Rivers Street
Boone, NC 28608
Phone: 828 262 2755
Fax: 828 262 6558
 
--- For more information about the DCHAS-L e-mail list, contact the Divisional membership chair at membership**At_Symbol_Here**dchas.org Follow us on Twitter **At_Symbol_Here**acsdchas
--- For more information about the DCHAS-L e-mail list, contact the Divisional membership chair at membership**At_Symbol_Here**dchas.org Follow us on Twitter **At_Symbol_Here**acsdchas

Previous post   |  Top of Page   |   Next post



The content of this page reflects the personal opinion(s) of the author(s) only, not the American Chemical Society, ILPI, Safety Emporium, or any other party. Use of any information on this page is at the reader's own risk. Unauthorized reproduction of these materials is prohibited. Send questions/comments about the archive to secretary@dchas.org.
The maintenance and hosting of the DCHAS-L archive is provided through the generous support of Safety Emporium.