Cameo lists gives a reactivity alert "Strong Oxidizing Agent. incompatible with hydrochloric acid and easily oxidizes organic materials. Contact with other materials may cause fire."NIOSH under incompatibilities & Reactivities " Hydrochloric acid, easily oxidized organic materials [Note: Begins to sublime below BP. Contact with other materials may cause fire.]"
--- For more information about the DCHAS-L e-mail list, contact the Divisional membership chair at membership**At_Symbol_Here**dchas.org Follow us on Twitter **At_Symbol_Here**acsdchasHello
I'm currently working on Chemical SOPs.
While working on Osmium Tetroxide I've been looking at other SOP's from other Colleges/Universities and many say it is a strong oxidizer. Which makes sense but when you look at the SDS sheets and in particular the GHS for this chemical; oxidizer isn't listed as a hazard. I'm looking at it in a solution and by itself (100%) and still no oxidizer warning.
Any guidance would be greatly appreciated.
Thanks
Jeffrey R. Cogswell, Ph.D.
Chemical Inventory and Laboratory Resource Center Technician, EHS
37 Dewey Field Road, HB 6216
Hanover, New Hampshire 03755
P: 603.359.0128 F: 603.646.2622
http://www.dartmouth.edu/~ehs/
Previous post | Top of Page | Next post