From: Michael <mabuczynski**At_Symbol_Here**HOTMAIL.COM>
Subject: Re: [DCHAS-L] Need help on a ventilation problem
Date: Tue, 21 Aug 2018 12:49:09 +0000
Reply-To: ACS Division of Chemical Health and Safety <DCHAS-L**At_Symbol_Here**PRINCETON.EDU>
Message-ID: BN6PR1801MB198629FAF1B9E759DBFE6CDCAB310**At_Symbol_Here**BN6PR1801MB1986.namprd18.prod.outlook.com
In-Reply-To


Try contacting the manufacturer of the LCs. Equipment manufacturers will often sell local exhaust attachments for their machines or tell you who might.

Mike Buczynski
Sr EHSAdvisor Product Stewardship,Regulatory Affairs
Afton Chemical
Richmond VA

On Aug 21, 2018, at 8:42 AM, Daniel C Herrick <herrickd**At_Symbol_Here**MIT.EDU> wrote:

Hi Monona,

It would seem to me that the hazards of ventilating these two laser cutters together should be minimal (though I don't have any data to "prove" this) since as you note the metal fume should be metal oxide fume almost immediately I would think.  One suggestion could be to restrict metal cutting to only be done on the laser cutter furthest downstream aka closest to the exhaust?  Though wood particulate from the other LC could still intermingle so maybe this would make no difference.  And any "restriction" like that would likely only work in a staffed space...much more difficult in a student-run environment (though possible with diligent enough students).

I'm just glad to hear they (whoever They are) are going to ventilate their laser cutters properly with ducted exhaust!

Dan

(from the ACS National Meeting in Boston where I've been extolling the virtues of DCHAS, in particular the DCHAS-L as an amazing resource (thanks to Ralph and Rob and the many others who help make the listserv go), and where Monona Rossol's name has come up several times as an amazing resource as well)

----------------------------------
Daniel C. Herrick, CIH
Senior EHS Coordinator, MIT MechE
617-253-2338; Room 3-449g

On Aug 21, 2018, at 7:56 AM, DCHAS Membership Chair <membership**At_Symbol_Here**DCHAS.ORG> wrote:

From: Monona Rossol <actsnyc**At_Symbol_Here**cs.com>
Re: Need help on a ventilation problem

I've been asked if two large laser cutters can be branch-ducted together. The problem is they will be used to cut wood, plastic, leather, and metal at various times. This means metal fumes can be in the ducts at the same time as smoke from potentially combustible materials. Since the metal will be in a fume, that is, a metal oxide form, it isn't clear that the combination would be hazardous.

Any and all opinions on the potential hazards or lack thereof are eagerly awaited.

Monona Rossol in Amherst teaching the art safety course.

---
For more information about the DCHAS-L e-mail list, contact the Divisional membership chair at membership**At_Symbol_Here**dchas.org
Follow us on Twitter **At_Symbol_Here**acsdchas
--- For more information about the DCHAS-L e-mail list, contact the Divisional membership chair at membership**At_Symbol_Here**dchas.org Follow us on Twitter **At_Symbol_Here**acsdchas

Previous post   |  Top of Page   |   Next post



The content of this page reflects the personal opinion(s) of the author(s) only, not the American Chemical Society, ILPI, Safety Emporium, or any other party. Use of any information on this page is at the reader's own risk. Unauthorized reproduction of these materials is prohibited. Send questions/comments about the archive to secretary@dchas.org.
The maintenance and hosting of the DCHAS-L archive is provided through the generous support of Safety Emporium.