Hi Joe,
We just implemented a new program for management of peroxide forming materials. We are using the low range Quantofix test strips, and are doing a pass/fail instead of threshold value. We are doing that for all
classes of peroxide forming materials.
All the best,
Kristi
From: ACS Division of Chemical Health and Safety [mailto:DCHAS-L**At_Symbol_Here**PRINCETON.EDU]
On Behalf Of Pavlak, Edmund J
Sent: Wednesday, January 31, 2018 7:35 AM
To: DCHAS-L**At_Symbol_Here**PRINCETON.EDU
Subject: [DCHAS-L] Peroxide forming compound testing program
Does anyone have a testing program in which peroxide forming chemicals are tested? If so, what methodology are you using? Do you have a threshold value for disposal, and is it for all peroxide formers or are there different thresholds
specific to certain chemicals?
Thanks for your help.
Joe Pavlak
Chemical Management System
Safety and Health Services Division
Brookhaven National Laboratory
Building 120
Upton, NY 11973
631-344-2028 office
631-831-3692 cell