From: James Wright <jhwright**At_Symbol_Here**UCHICAGO.EDU>
Subject: Re: [DCHAS-L] Why are QC/Qa labs not covered by the Lab Standard?
Date: Thu, 4 Feb 2016 17:17:24 +0000
Reply-To: DCHAS-L <DCHAS-L**At_Symbol_Here**MED.CORNELL.EDU>
Message-ID: CF313F63ED06074598E47C9074ABBE62F64938**At_Symbol_Here**xm-mbx-09-prod
In-Reply-To <54A9E55E-764F-42D7-A69C-FBAF3295308C**At_Symbol_Here**keene.edu>


UCLA was cited four times for non-compliance with the lab standard (Title 8 5191) in 2009 by Cal/OSHA. https://urldefense.proofpoint.com/v2/url?u=https-3A__www.osha.gov_pls_imis_establishment.inspection-5Fdetail-3Fid-3D126203017&d=BQIFAg&c=lb62iw4YL4RFalcE2hQUQealT9-RXrryqt9KZX2qu2s&r=meWM1Buqv4IQ27AlK1OJRjcQl09S1Zta6YXKalY_Io0&m=_Z82GlAjtbYdyPfE45cBtr4xHeF3wH_GTZyQebaXlLk&s=GiKadod-Lt8p2IkvPu4AiC9e98ICyrcwI1od432ibHo&e=
Also this citation was discussed by Jyllian Kemsley (https://urldefense.proofpoint.com/v2/url?u=http-3A__cenblog.org_the-2Dsafety-2Dzone_2010_11_ucla-2Dcalosha-2Dsettlement_&d=BQIFAg&c=lb62iw4YL4RFalcE2hQUQealT9-RXrryqt9KZX2qu2s&r=meWM1Buqv4IQ27AlK1OJRjcQl09S1Zta6YXKalY_Io0&m=_Z82GlAjtbYdyPfE45cBtr4xHeF3wH_GTZyQebaXlLk&s=4mwQF5MDnokGWLLAuw03NZI6N6tXoHrhS-LsEZgDwRY&e= ) because of one of the citations related to the previous CHO being deemed unqualified.

The best rationale I can think of that QC/QA could be argued as part of the production process. As part of the production process it does not meet the definition of laboratory use of hazardous chemicals.

--
James H. Wright, PhD
Chemical Safety Officer
The University of Chicago
Office of Research Safety
5730 S. Ellis Ave, Crerar Library Rm 018
Chicago, IL 60637
Phone: (773)702-5907
jhwright**At_Symbol_Here**uchicago.edu

-----Original Message-----
From: DCHAS-L Discussion List [mailto:dchas-l**At_Symbol_Here**med.cornell.edu] On Behalf Of Stuart, Ralph
Sent: Thursday, February 04, 2016 10:28 AM
To: DCHAS-L**At_Symbol_Here**MED.CORNELL.EDU
Subject: Re: [DCHAS-L] Why are QC/Qa labs not covered by the Lab Standard?

> >I do not understand the point of the distinction. The end result would be to bind QC/QA labs to the OSHA regulations for large production level quantities of chemicals.
>
I think that this is a distinction without a difference. As far as I can tell, OSHA has not cited anyone under the lab standard for at least 10 years, if ever (I've asked OSHA for an instance and they couldn't come up with one). As discussed at https://urldefense.proofpoint.com/v2/url?u=http-3A__cenblog.org_the-2Dsafety-2Dzone_2016_01_trimethylaluminum-2Dexplosion-2Dat-2Ddow-2Dfacility-2Din-2Dmassachusetts_&d=BQIFAg&c=lb62iw4YL4RFalcE2hQUQealT9-RXrryqt9KZX2qu2s&r=meWM1Buqv4IQ27AlK1OJRjcQl09S1Zta6YXKalY_Io0&m=wuNl3uYe9LIMs9oeFvmXKzS-SU2a0-FRVulm5vi1Sa4&s=9V3hZp63hxnjw48r5rZY47JdNbfcdXdeanGBaEwxGK4&e=
even OSHA citations that involve lab operations use more generic standards such as the HazCom or PPE requirements rather than the lab standard, most likely for simplicity of the enforcement adminstration.

With this in mind, if you have a operation that meets the OSHA definition of lab scale and you feel that a Chemical Hygiene Plan approach will improve your safety program, I would write a CHP that addresses lab safety for your operations. This effort can only add value to a regulatory interaction with OSHA involving those operations. An example of such an operation could be an art studio that operates with small enough amounts of chemicals to be considered lab scale. I would note that I have seen many art studios that wouldn't meet that definition and/or have other hazards that wouldn't be included in a CHP (e.g. welding).

Thanks for any interesting question.

- Ralph

Ralph Stuart, CIH, CCHO
Chemical Hygiene Officer
Keene State College

ralph.stuart**At_Symbol_Here**keene.edu

Previous post   |  Top of Page   |   Next post



The content of this page reflects the personal opinion(s) of the author(s) only, not the American Chemical Society, ILPI, Safety Emporium, or any other party. Use of any information on this page is at the reader's own risk. Unauthorized reproduction of these materials is prohibited. Send questions/comments about the archive to secretary@dchas.org.
The maintenance and hosting of the DCHAS-L archive is provided through the generous support of Safety Emporium.