From: "Wright, Mike" <mwright**At_Symbol_Here**USW.ORG>
Subject: Re: [DCHAS-L] Gas Leak Training Input
Date: Mon, 21 Dec 2015 11:36:40 +0000
Reply-To: DCHAS-L <DCHAS-L**At_Symbol_Here**MED.CORNELL.EDU>
Message-ID: 673A00C44C25834BA3198AADFC1EB7AE297C0E74**At_Symbol_Here**PIT-MAIL01.uswa-us.local
In-Reply-To <151b75bd120-6c6d-26c**At_Symbol_Here**webprd-a56.mail.aol.com>


Thanks, Monona.  These days the steel industry uses it for gas rescue training, when they use it all, and everyone is in a SCBA, for which they've been trained. And most times we use nothing at all, since the gas we are most worried about is CO. The fog enhances the training by creating an additional visibility challenge. But I appreciate the advice. We worked hard to get a good program in place after a devastating series of accidents in the 70s. We went from 7 deaths in 1979 and 3 in 1980 to a total of 3 in plants covered by the agreement in the 35 years since. But we always have to go back and check to see that the programs are being followed, evaluated and upgraded.

 

Michael J. Wright

Director of Health, Safety and Environment

United Steelworkers

 

412-562-2580 office

412-370-0105 cell

 

See us on the web at www.usw.org

 

From: DCHAS-L Discussion List [mailto:dchas-l**At_Symbol_Here**med.cornell.edu] On Behalf Of Monona Rossol
Sent: Friday, December 18, 2015 6:10 PM
To: DCHAS-L**At_Symbol_Here**MED.CORNELL.EDU
Subject: Re: [DCHAS-L] Gas Leak Training Input

 

Re Theatrical Fog: Just came home after 5 hours of deposition in a case of an alleged death attributed to theatrical fog. If people are going to breathe this stuff, there are professional theatrical standards for use that are recommended by the manufacturers. Visit www.plasa.org and find their standards download feature and look for ANSI E1.5, E1.14, E1.23 and E1.29.  E1.5 will provide the TWA and peak (ceiling) limits recommended.  I recommend even less, but then......

 

You will also need to rent a Thermo MIE PDR-1000AN particle counter and use the calibration factor for the particular machine and type of fog you use.  

 

If you need advice, I'm here.

 

Monona Rossol, M.S., M.F.A., Industrial Hygienist

President:  Arts, Crafts & Theater Safety, Inc.

Safety Officer: Local USA829, IATSE

181 Thompson St., #23

New York, NY 10012     212-777-0062

actsnyc**At_Symbol_Here**cs.com   www.artscraftstheatersafety.org


 

 

-----Original Message-----
From: Wright, Mike <mwright**At_Symbol_Here**USW.ORG>
To: DCHAS-L <DCHAS-L**At_Symbol_Here**MED.CORNELL.EDU>
Sent: Fri, Dec 18, 2015 2:06 pm
Subject: Re: [DCHAS-L] Gas Leak Training Input

Gas rescue training in the steel industry uses theatrical fog. But you need to train people to a high level before using it, since the visibility problem adds a whole new dimension. Several years ago one company stupidly decided that everyone who worked in a gas hazard area should be trained in gas rescue. They gave people very limited training in SCBA use - basically how to don it - then threw them into a simulated rescue with a mannequin in a dark, foggy space. One worker died of a heart attack.

 

 

Michael J. Wright

Director of Health, Safety and Environment

United Steelworkers

 

412-562-2580 office

412-370-0105 cell

 

See us on the web at www.usw.org

 

From: DCHAS-L Discussion List [mailto:dchas-l**At_Symbol_Here**med.cornell.edu] On Behalf Of Herriott, Carole
Sent: Friday, December 18, 2015 12:27 PM
To: DCHAS-L**At_Symbol_Here**MED.CORNELL.EDU
Subject: Re: [DCHAS-L] Gas Leak Training Input

 

Would dry ice in water work?

 

-Carole

"Simplicity involves unburdening your life, and living more lightly with fewer distractions that interfere with a high quality life, as defined uniquely by each individual."

 - Linda Breen Pierce

 

From: DCHAS-L Discussion List [mailto:dchas-l**At_Symbol_Here**med.cornell.edu] On Behalf Of Samantha D
Sent: Friday, December 18, 2015 8:37 AM
To: DCHAS-L**At_Symbol_Here**MED.CORNELL.EDU
Subject: [DCHAS-L] Gas Leak Training Input

 

Hi all,

 

I'm trying to put together a gas leak training for our ERT members and I can't quite decide how to set it up. If the gas was visible, that would be nice but I can't think of a good candidate. Have any of you done anything like this? If so, any ideas or input into how to get this training onto it's feet would be much appreciated.

 

I already have liquid spill training planned out.

 

Thank you!


Samantha Lushtak

Atmel Corporation

Environmental, Health, and Safety Engineer

Previous post   |  Top of Page   |   Next post



The content of this page reflects the personal opinion(s) of the author(s) only, not the American Chemical Society, ILPI, Safety Emporium, or any other party. Use of any information on this page is at the reader's own risk. Unauthorized reproduction of these materials is prohibited. Send questions/comments about the archive to secretary@dchas.org.