From: Monona Rossol <actsnyc**At_Symbol_Here**cs.com>
Subject: Re: [DCHAS-L] Gas Leak Training Input
Date: Fri, 18 Dec 2015 18:10:26 -0500
Reply-To: DCHAS-L <DCHAS-L**At_Symbol_Here**MED.CORNELL.EDU>
Message-ID: 151b75bd120-6c6d-26c**At_Symbol_Here**webprd-a56.mail.aol.com
In-Reply-To <673A00C44C25834BA3198AADFC1EB7AE297BF419**At_Symbol_Here**PIT-MAIL01.uswa-us.local>


Re Theatrical Fog: Just came home after 5 hours of deposition in a case of an alleged death attributed to theatrical fog. If people are going to breathe this stuff, there are professional theatrical standards for use that are recommended by the manufacturers. Visit www.plasa.org and find their standards download feature and look for ANSI E1.5, E1.14, E1.23 and E1.29.  E1.5 will provide the TWA and peak (ceiling) limits recommended.  I recommend even less, but then......


You will also need to rent a Thermo MIE PDR-1000AN particle counter and use the calibration factor for the particular machine and type of fog you use.  

If you need advice, I'm here.


Monona Rossol, M.S., M.F.A., Industrial Hygienist
President:  Arts, Crafts & Theater Safety, Inc.
Safety Officer: Local USA829, IATSE
181 Thompson St., #23
New York, NY 10012     212-777-0062
actsnyc**At_Symbol_Here**cs.com   www.artscraftstheatersafety.org

 


-----Original Message-----
From: Wright, Mike <mwright**At_Symbol_Here**USW.ORG>
To: DCHAS-L <DCHAS-L**At_Symbol_Here**MED.CORNELL.EDU>
Sent: Fri, Dec 18, 2015 2:06 pm
Subject: Re: [DCHAS-L] Gas Leak Training Input

Gas rescue training in the steel industry uses theatrical fog. But you need to train people to a high level before using it, since the visibility problem adds a whole new dimension. Several years ago one company stupidly decided that everyone who worked in a gas hazard area should be trained in gas rescue. They gave people very limited training in SCBA use - basically how to don it - then threw them into a simulated rescue with a mannequin in a dark, foggy space. One worker died of a heart attack.
 
 
Michael J. Wright
Director of Health, Safety and Environment
United Steelworkers
 
412-562-2580 office
412-370-0105 cell
 
See us on the web at www.usw.org
 
From: DCHAS-L Discussion List [mailto:dchas-l**At_Symbol_Here**med.cornell.edu] On Behalf Of Herriott, Carole
Sent: Friday, December 18, 2015 12:27 PM
To: DCHAS-L**At_Symbol_Here**MED.CORNELL.EDU
Subject: Re: [DCHAS-L] Gas Leak Training Input
 
Would dry ice in water work?
 
-Carole
"Simplicity involves unburdening your life, and living more lightly with fewer distractions that interfere with a high quality life, as defined uniquely by each individual."
 - Linda Breen Pierce
 
From: DCHAS-L Discussion List [mailto:dchas-l**At_Symbol_Here**med.cornell.edu] On Behalf Of Samantha D
Sent: Friday, December 18, 2015 8:37 AM
To: DCHAS-L**At_Symbol_Here**MED.CORNELL.EDU
Subject: [DCHAS-L] Gas Leak Training Input
 
Hi all,
 
I'm trying to put together a gas leak training for our ERT members and I can't quite decide how to set it up. If the gas was visible, that would be nice but I can't think of a good candidate. Have any of you done anything like this? If so, any ideas or input into how to get this training onto it's feet would be much appreciated.
 
I already have liquid spill training planned out.
 
Thank you!

Samantha Lushtak
Atmel Corporation
Environmental, Health, and Safety Engineer

Previous post   |  Top of Page   |   Next post



The content of this page reflects the personal opinion(s) of the author(s) only, not the American Chemical Society, ILPI, Safety Emporium, or any other party. Use of any information on this page is at the reader's own risk. Unauthorized reproduction of these materials is prohibited. Send questions/comments about the archive to secretary@dchas.org.
The maintenance and hosting of the DCHAS-L archive is provided through the generous support of Safety Emporium.