It's all a matter of kinetics and mass/heat transfer.  Unless you are doing something completely inappropriate - like trying to ignite thermite inside a dry vessel submurged in a dry ice/acetone bath, this is not normally a concern.  Most lab reactions are exothermic, and many would qualify as "significantly" exothermic if done at room temperature - for example, quenching a Grignard reaction, nitrations etc.


I'll generalize more to  say that it's really a matter of ensuring your have enough solvent to absorb any heat rise, a condenser, a properly selected bath to transfer the heat from the vessel, effective stirring etc.    I have seen a number of reactions run away because the stirring stopped or became unobservable due to precipitation or other factors.  Added reagent then causes a very localized and very hot spot --> up it goes.

If you have the specific procedure, I'd be happy to follow up on or off-list.   Is this something that other folks might have an SOP for?

Rob Toreki

 ======================================================
Safety Emporium - Lab & Safety Supplies featuring brand names
you know and trust.  Visit us at http://www.SafetyEmporium.com
esales**At_Symbol_Here**safetyemporium.com  or toll-free: (866) 326-5412
Fax: (856) 553-6154, PO Box 1003, Blackwood, NJ 08012




On Sep 3, 2015, at 8:25 AM, "Stuart, Ralph" <Ralph.Stuart**At_Symbol_Here**keene.edu> wrote:

Stuff that needs more careful attention is anything that will be subjected to vacuum or pressure.

Thanks for this information. The procedure I'm looking today at involves temperature considerations. Because the reaction in the glassware is significantly exothermic, so it will be contained in the ice bath. Are temperature stresses likely to be of concern for lab glassware without visible chips or cracks?

- Ralph

Ralph Stuart, CIH, CCHO
Chemical Hygiene Officer
Keene State College

ralph.stuart**At_Symbol_Here**keene.edu


Previous post   |  Top of Page   |   Next post



The content of this page reflects the personal opinion(s) of the author(s) only, not the American Chemical Society, ILPI, Safety Emporium, or any other party. Use of any information on this page is at the reader's own risk. Unauthorized reproduction of these materials is prohibited. Send questions/comments about the archive to secretary@dchas.org.
The maintenance and hosting of the DCHAS-L archive is provided through the generous support of Safety Emporium.