From: "Tobias, Bruce" <btobias**At_Symbol_Here**WELLSTAT.COM>
Subject: Re: [DCHAS-L] Built in eyewash drainage alternatives?
Date: Wed, 5 Aug 2015 13:25:49 +0000
Reply-To: DCHAS-L <DCHAS-L**At_Symbol_Here**MED.CORNELL.EDU>
Message-ID: CCBC148804413C439E68A8C69CB845A90C7D9627**At_Symbol_Here**WMEX3.pro-virus.com
In-Reply-To <4E1CACC5-D8BB-48C8-B552-26C5A7543BA3**At_Symbol_Here**keene.edu>


Yes I have seen many eyewashes like this, often installed as a low-cost way to correct a safety problem. Eyewashes are typically (I hope) plumbed to facilitate flushing when installed during new construction or as part of a major renovation.

You have a few options for non-plumbed eyewashes with a low drain:

1) Cut the drain pipe higher above the floor, if possible, to provide room for a larger collection container;

2) Find or make a low but high-volume plastic collection container that fits under the drain;

3) Use flexible tubing to direct the effluent to the floor drain; or

4) Contact the facilities department to see if the eyewash can be plumbed into a handy drain line.

Good luck!

-----Original Message-----
From: DCHAS-L Discussion List [mailto:dchas-l**At_Symbol_Here**med.cornell.edu] On Behalf Of Stuart, Ralph
Sent: Wednesday, August 5, 2015 8:25 AM
To: DCHAS-L**At_Symbol_Here**MED.CORNELL.EDU
Subject: [DCHAS-L] Built in eyewash drainage alternatives?

Another question from this week‰??s lab inspections:

We have a 2004 Science building with eyewashes built into the wall (similar to the design found at https://urldefense.proofpoint.com/v2/url?u=http-3A__www.eyewashdirect.com_Bradley-2DS19294HB-2DBarrier-2DFree-2DEyewash-2Dw-2DTailpiece-2Dp_s19294hb.htm&d=BQIGaQ&c=lb62iw4YL4RFalcE2hQUQealT9-RXrryqt9KZX2qu2s&r=meWM1Buqv4IQ27AlK1OJRjcQl09S1Zta6YXKalY_Io0&m=EVo3tbkOvis_mZs4Ub41BYWHRcWLULcsLsexjSt5GMA&s=xM9PVi18EaMDhCtVyzxv7LI9sjPW1BE7hK0Sp0SB0fA&e= ). When the eyewash is activated, the water flows back into the drain in the wall and then expelled onto the floor under the eyewash in an ever-growing puddle. My immediate concern is that the water comes out of a pipe which is between 6 and 10 inches from the floor. (There is a floor drain in the area of the pipe which serves the safety shower as well.) The imedidate problem is that location of the drain pipe is low enough that collecting water from it when flushing the eyewash is difficult; we currently use a secondary containment b!
in tipped under the pipe in such a way that we‰??re able to collect about 1/3 of the capacity of th!
e bin.

I wonder if anyone on the list has developed a modification to this design that is reasonably priced (we‰??re talking about 20 units with this condition) that would allow for collection of the flush water in a way that is convenient for the person conducting the flushing? This design also presents challenges for the emergency eyewash use case, but that‰??s not my primary motivation in considering modifications; I‰??m more concerned with enabling more frequent flushing of the eyewashes.

Thanks for any experience with this question.

- Ralph

Ralph Stuart, CIH, CCHO
Chemical Hygiene Officer
Keene State College

ralph.stuart**At_Symbol_Here**keene.edu

Previous post   |  Top of Page   |   Next post



The content of this page reflects the personal opinion(s) of the author(s) only, not the American Chemical Society, ILPI, Safety Emporium, or any other party. Use of any information on this page is at the reader's own risk. Unauthorized reproduction of these materials is prohibited. Send questions/comments about the archive to secretary@dchas.org.
The maintenance and hosting of the DCHAS-L archive is provided through the generous support of Safety Emporium.