I think it is tragic that we do NOT have a Lessons Learned database where reports such as the dozen just posted can be placed and we can learn. This missed opportunity is ######### (sorry, all the words that come to mind should not appear in an email

 

 

------------------------------------------------------------------------------------

The information contained in this message is privileged and confidential and protected from disclosure. If the reader of this message is not the intended recipient, or an employee or agent responsible for delivering this message to the intended recipient, you are hereby notified that any dissemination, distribution or copying of this communication is strictly prohibited. If you have received this communication in error, please notify us immediately by replying to the message and deleting it from your computer.

 

ACSafety has a new address:

NEAL LANGERMAN, Ph.D.

ADVANCED CHEMICAL SAFETY, Inc.

PO Box 152329

SAN DIEGO CA 92195

011(619) 990-4908 (phone, 24/7)

www.chemical-safety.com

 

We no longer support FAX.

 

 Please contact me before sending any packages or courier delivery.  The address for those items is:

5340 Caminito Cachorro

San Diego CA 92105

 

 

From: DCHAS-L Discussion List [mailto:dchas-l**At_Symbol_Here**med.cornell.edu] On Behalf Of Don Abramowitz
Sent: Thursday, July 02, 2015 9:13 AM
To: DCHAS-L**At_Symbol_Here**MED.CORNELL.EDU
Subject: Re: [DCHAS-L] Glassware injury lesson learned report?

 

Two here, over the years:

Using a rotary evaporator, a grad student attempted to disconnect the distillation flask from the vapor tube, where it was attached by a ground glass connection.  When it stuck, torque was applied and the male fitting snapped, leaving a sharp edge that made a cut to the back of the hand above the thumb holding the flask that required several stitches.

Also, another insertion of a pipette into the "safety" rubber pipette filler for you.  Pressure not applied in a straight line, (both objects held freehand) pipette snapped, and punctured the hand holding the filler in same position as above injury.   In addition to stitches, some nerve damage plus fainting at the sight of blood.  

Don

Donald Abramowitz, CIH
Environmental Health & Safety Officer
Bryn Mawr College
Bryn Mawr, PA

 

 


Does anyone have a relatively detailed favorite Lessons Learned report for a situation which involves significant cuts from broken glassware in a lab that doesn't involve over-pressurization of the vessel? I'm doing a training next week for undergraduate students and I'd like to make the point that it's not always the chemistry that creates the problem. The example I have in mind could involve hot glassware that breaks when someone tries to pick it up and drops it, but similar events would be helpful as well.

Thanks for any assistance with this.

- Ralph

Ralph Stuart, CIH, CCHO
Chemical Hygiene Officer
Keene State College

ralph.stuart**At_Symbol_Here**keene.edu

Previous post   |  Top of Page   |   Next post



The content of this page reflects the personal opinion(s) of the author(s) only, not the American Chemical Society, ILPI, Safety Emporium, or any other party. Use of any information on this page is at the reader's own risk. Unauthorized reproduction of these materials is prohibited. Send questions/comments about the archive to secretary@dchas.org.