From: "CHANDRA, Tilak" <tchandra**At_Symbol_Here**FPM.WISC.EDU>
Subject: Re: [DCHAS-L] University of Utah Chemistry Building - small explosion
Date: Fri, 17 Apr 2015 16:30:48 +0000
Reply-To: DCHAS-L <DCHAS-L**At_Symbol_Here**MED.CORNELL.EDU>
Message-ID: AC64846C6B11EE4F97DEDF3ED857D65C31BFEED9**At_Symbol_Here**aims-mbx-02.aims.wisc.edu
In-Reply-To <8D4D1ADC-BC88-449B-B5FB-2C1537442B4A**At_Symbol_Here**verizon.net>


I completely agree withReinhard. My additions: There is a possibility of sudden storage shelves collapse due to high acid/base corrosion, if the shelves are not maintained well.

 

Tilak

 

From: DCHAS-L Discussion List [mailto:dchas-l**At_Symbol_Here**MED.CORNELL.EDU]On Behalf Of r.sidor**At_Symbol_Here**verizon.net
Sent: Friday, April 17, 2015 10:48 AM
To: DCHAS-L**At_Symbol_Here**MED.CORNELL.EDU
Subject: Re: [DCHAS-L] University of Utah Chemistry Building - small explosion

 

I don't think that the safety system worked.  Chemical storage cabinets are not designed to contain explosions.  For containment of unstable, potentially explosive materials, an explosion resistant room, with pressure relieving walls is required.

 

As others have stated the involved material was possibly unstable or chemically incompatibles were stored together.  This speaks to the education of the owner about chemical storage safety issues, and the adequacy of the chemical safety audit program of the institution - to check chemical storage practices.

 

And as to the need to have fans to exhaust gases and fumes from the building, was there not the capacity to change the lab HVAV system from its normal return/recycle mode over to exhaust directly to the outside.  This would place the involved space under negative pressure, avoiding spread of the gases/fumes/smoke to uninvolved spaces?  Also, was the lab space HVAC system separate from the HVAC system servicing the hallway, offices, and support spaces?  This would further limit the spread of airborne hazards support and allow for safer exit of building occupants.

 

Reinhard Sidor, ScD

Safety & Hygiene - retired

GE Global Research

Schenectady, NY

 



Sent from my iPad


On Apr 17, 2015, at 10:59 AM, George D. McCallion <medchem**At_Symbol_Here**COMCAST.NET> wrote:

DCHAS members,

 

From what I could decipher, it seems like a possible delayed exotherm from a storage container (flask, bottle). What was the material, etc.? Cannot say at this point, and speculation would be moot.

 

It does seem that the cabinetry did perform effectively, which is always a good thing.

 

The vapors identified may not have been emulating from the point-of-incidence; hopefully a follow up will be forthcoming that we can all read and discuss.

 

Thanks for posting this, Dean.

 

Cheers!

 

-George

 


From:"Dean Lillquist" <lillquistd**At_Symbol_Here**GMAIL.COM>
To: DCHAS-L**At_Symbol_Here**MED.CORNELL.EDU
Sent: Friday, April 17, 2015 9:55:11 AM
Subject: [DCHAS-L] University of Utah Chemistry Building - small explosion

 

http://www.ksl.com/?sid=34263740&nid=148&title=u-chemistry-building-evacuated-after-small-explosion&s_cid=queue-19

 

The take-home message from them:

 

Overall, he said, the safety measures that were in place did what they were designed to do.

"The cabinet did its job," he said. "It's proof that those safety measures work."

 

I would like to seen their  after action investigation report.

Their engineering controls did appear to work.  ButÉ

"An ounce of prevention is worth a pound of cure."

                                             Benjamin Franklin

I wonder about their administrative controls in place - especially their chemical storage and inventory program. 

I might speculate a chemical storage issue: incompatibility and/or chemical expiration issue. 

If this was the root cause, it would have been preventable.

 

Previous post   |  Top of Page   |   Next post



The content of this page reflects the personal opinion(s) of the author(s) only, not the American Chemical Society, ILPI, Safety Emporium, or any other party. Use of any information on this page is at the reader's own risk. Unauthorized reproduction of these materials is prohibited. Send questions/comments about the archive to secretary@dchas.org.