The NFPA or HMIS labels, or something from another "competent authority" are for workplace containers you transfer chemicals to.  But you're right, you don't need that if you're using the original distributor's labeling. 

 

In my opinion the NFPA and HMIS labels are basically a courtesy for fire fighters.    

 

One problem with just using those pictogram placards is you still have to be careful about the corrosives, because it doesn't distinguish between acids and bases - or even that DOT quarter-inch steel corrosive definition that has nothing to do with pH.  So if somebody's not careful and sorts chemicals solely based on the pictograms, they just might put all the acids and bases in the same cabinet.  So you have to make sure everybody in the lab understands that, and exactly what those chemicals are that they're dealing with. 

 

Eric

 

Eric Clark, MS, CHMM, CCHO

Safety Officer, Public Health Scientist III

Los Angeles County Public Health Laboratory

 

 

From: DCHAS-L Discussion List [mailto:dchas-l**At_Symbol_Here**MED.CORNELL.EDU]On Behalf Of George D. McCallion
Sent: Friday, October 17, 2014 8:13 AM
To: DCHAS-L**At_Symbol_Here**MED.CORNELL.EDU
Subject: [DCHAS-L] GHS and NFPA query

 

Dear DCHAS members,

It seems that from the attached OSHA HazComm info,

https://www.osha.gov/Publications/HazComm_QuickCard_Labels.html

The NFPA labeling might no longer be required. From a Hazardous Materials Technician level (completing this in Oct.) I would use that placard as fist line if identification. Any ideas as to why it might not be required?

 

Thank you in advance.

 

Sincerely,

George

 

*******************************************************

George D. McCallion
124 Magnolia Court
Collegeville, PA 19426

 

Voice: 610.888.2436
Email: medchem**At_Symbol_Here**comcast.net
https://www.linkedin.com/in/georgedmccallion

*******************************************************

Previous post   |  Top of Page   |   Next post



The content of this page reflects the personal opinion(s) of the author(s) only, not the American Chemical Society, ILPI, Safety Emporium, or any other party. Use of any information on this page is at the reader's own risk. Unauthorized reproduction of these materials is prohibited. Send questions/comments about the archive to secretary@dchas.org.
The maintenance and hosting of the DCHAS-L archive is provided through the generous support of Safety Emporium.