The Risk Management Committee at my college is revamping our "Emergency Protocol Guide" for campus.  Regarding chemical spills, they have asked me what should be on the chart when there is a chemical spill.

 

One member suggested that when a large spill occurs, the person should pull the fire alarm. Even for a pretty nasty spill, I am uncomfortable with that recommendation.  I am worried that

As a relatively new CHO, it seems to me that for chemical spills, the protocol would be to have a person call the FD if a chemistry professor determines that it is necessary.

 

In my teaching career, we have only had one nasty spill (boiling nitric acid spilled out of the hood and everyone started choking), which we mitigated by evacuating the lab and waiting until the lab ventilation system cleaned most of it out. Then we went in and mopped it up with bicarbonate.

 

I am interested in your thoughts, advice or experiences.

 

Kyle

 

 

Kyle Strode

Associate Professor of Chemistry

Carroll College

1601 N. Benton Ave.

Helena, MT 59625-0002

(406) 447-5564

Previous post   |  Top of Page   |   Next post



The content of this page reflects the personal opinion(s) of the author(s) only, not the American Chemical Society, ILPI, Safety Emporium, or any other party. Use of any information on this page is at the reader's own risk. Unauthorized reproduction of these materials is prohibited. Send questions/comments about the archive to secretary@dchas.org.
The maintenance and hosting of the DCHAS-L archive is provided through the generous support of Safety Emporium.