49 CFR 180.205 (c) does specifically state
that "...a cylinder filled before the requalification becomes due
may remain in service until it is emptied."
180.205 General requirements for requalification of
specification cylinders.
...
(c)
Periodic requalification of cylinders.
Each cylinder bearing a DOT specification marking must
be requalified and marked as specified in the Requalification Table in
this subpart. Each cylinder bearing a DOT special permit
number must be requalified and marked in conformance with
this section and the terms of the applicable special permit. No cylinder
may be filled with a hazardous material and offered
for transportation in commerce unless that cylinder has
been successfully requalified and marked in accordance with this subpart.
A cylinder may be requalified at any time during or
before the month and year that the requalification is
due. However, a cylinder filled before the requalification becomes due
may remain in service until it is emptied. [emphasis added] A cylinder
with a
specified service life may not be refilled and offered
for transportation after its authorized service life has expired.
-Kevin
*********************************************************
Kevin J. Beltis
Director of Health, Safety and Environment
TIAX LLC
Office: 781.879.1222
FAX: 781.879.1202
Mobile: 508.934.9382
Address:
35 Hartwell Avenue
Lexington, MA 02421-3102
TIAX, "Powered by Innovation"
*******************************************************
TIAX, LLC is a privately held company at the intersection of business and
technology. TIAX builds on a rich heritage based on creating business opportunities
and growth through the power of science, technology, and innovation.
From:
"Carlos Rentas
Jr." <crentas1**At_Symbol_Here**NYC.RR.COM>
To:
DCHAS-L**At_Symbol_Here**MED.CORNELL.EDU
Date:
02/05/2014 05:30 PM
Subject:
Re: [DCHAS-L]
Hydrostatic Test Date
Sent by:
DCHAS-L Discussion
List <dchas-l**At_Symbol_Here**MED.CORNELL.EDU>
Ben,
In my experience, when I encountered a cylinder that upon
inspection had an expired hydrostatic date, we would remove the cylinder
from service, and return it to be retested and qualified. This is a legal
requirement as well as a best practice. (See 49 CFR 180.209 - REQUIREMENTS
FOR REQUALIFICATION OF SPECIFICATION CYLINDERS).
Carlos Rentas Jr., DPH CSP CHMM
Certified Safety, Health & Environmental Consultant
(888) 315-2498
Via iPhone 4S
On Feb 5, 2014, at 3:30 PM, JAKSAFETY**At_Symbol_Here**AOL.COM
wrote:
I would be prudent to not use a compressed
gas cylinder after its hydrostatic test date has expired.
Jim Kaufman
Laboratory Safety Institute
In a message dated 2/5/2014 12:00:35 A.M.
Eastern Standard Time, LISTSERV**At_Symbol_Here**listserv.med.cornell.edu
writes:
Date: Wed, 5 Feb 2014 01:54:50
+0000
From: Benjamin G Owens <bowens**At_Symbol_Here**UNR.EDU>
Subject: Gas Cylinder Hydrostatic Testing
All,
I understand that compressed gas cylinders must have a current hydrostatic
test to be filled. I have read a vendor site that indicates that
a cylinder may be transported after the hydrostatic test expiration date
if it was filled prior to the expiration date. If cylinders that
have exceeded the hydrostatic test date are considered safe to transport
are they considered safe to continue using? In other words, if a
compressed gas cylinder is not empty but has exceeded the hydrostatic test
expiration date is it required by regulation or prudent practice to be
returned for testing or can it continue to be used?
Thanks,
Ben
----------------------------------------------------
Ben Owens
Assistant Director, Laboratory Safety