From: Janet Baum <baum.janet**At_Symbol_Here**GMAIL.COM>
Subject: Re: [DCHAS-L] Laser lab design
Date: May 16, 2013 11:21:50 AM EDT
Reply-To: DCHAS-L <DCHAS-L**At_Symbol_Here**MED.CORNELL.EDU>
Message-ID: <861043627.2054169.1368714400478.JavaMail.root**At_Symbol_Here**sz0024a.emeryville.ca.mail.comcast.net>


Dear Wayne, There are sample laser laboratory layouts and discussion of laser laboratory safety issues in the 4th edition of Guidelines for Laboratory Design: Health, Safety, and Environmental Considerations, DiBerardinis, et al, 2013, published by Wiley. The ISBN is 978-0-470-50552-6. Lasers are discussed in Chapter 10, "Physics Laboratory". Lower power lasers are discussed in Chapter 5,"General or Analytical Chemistry Laboratory". Hope this helps you.
Janet Baum, AIA, DivCHAS
Washington University in St. Louis


On Thu, May 16, 2013 at 9:26 AM, <8524828hau**At_Symbol_Here**comcast.net> wrote:
Because your organization is in the construction mode for a lab building, I advise that installation of curtains is only one of many are other necessary architectural/engineering topics that need to be addressed -- e.g., interlocks for room access doors and optical shielding devices/enclosures, the location of seated work stations relative to the anticipated level of the beams, width of doors for transfer of laser tables with minimal disassembly, location for storage of protective eye wear, ventilation for heat loading (especially with the presence of curtains), non-relective wall surfaces, presence or absence of windows to the exterior, etc.

Therefore, I believe it would be prudent to purchase the 2012 (most recent) edition of the ANSI standard for Safe Use of Lasers in Research, Development and Testing (ANSI Z136.8-2012), available at http://webstore.ansi.org/RecordDetail.aspx?sku=ANSI+Z136.8-2012#.UZTkUCvcqxo. (BTW, there are other commercial sources of the ANSI standards.)

The text describing Z136.8-2012 concludes with the statement: "The standard is designed to be used in conjunction with the ANSI Z136.1."

ANSI's minimalist description of Z136.1 leads me to TENTATIVELY conclude that the difference between the two standards is the wavelength of the laser beam. I recommend that you acquire clarification from an ANSI representative, and be certain that the lab design is suitable for the full range of anticipated wavelengths (from UV to visible, and perhaps infrared). If you need both standards, ANSI offers the two as a set.

David Haugen
Retired in Illinois.



From: "Wayne Phan" <Wayne.Phan**At_Symbol_Here**POMONA.EDU>
To: DCHAS-L**At_Symbol_Here**MED.CORNELL.EDU
Sent: Wednesday, May 15, 2013 5:38:08 PM
Subject: [DCHAS-L]

Hello all,

We are in the processing of constructing a new lab building. We will be using class IV and class III lasers. Does anyone have standard regarding the outfitting of the lab (with safety curtains to divide the rooms)? Where can I find the standard.

Thanks,

-------------------------------------------------------------
This message has been scanned by Postini anti-virus software.


Previous post   |  Top of Page   |   Next post



The content of this page reflects the personal opinion(s) of the author(s) only, not the American Chemical Society, ILPI, Safety Emporium, or any other party. Use of any information on this page is at the reader's own risk. Unauthorized reproduction of these materials is prohibited. Send questions/comments about the archive to secretary@dchas.org.