The evaporation rate of mercury is fast (4 times butyl acetate)! =A0The vapours are heavy and will concentrate more at the floor. The vapours will penetrate the blood-brain and the blood-placenta barriers as methyl mercury do; thus a special risk for pregnant women.
It is correct that 5 mg Hg will not produce deadly concentrations in an average room but easily higher concentrations than many establish limit values (see table):
Tabel:
Limit values in
Air concentration (mg/m3) |
Explanation< /b> |
Authority |
10 |
Immediately Dangerous to Life and Health (IDLH) (30 min) |
NIOSH |
0,5 |
Limit value for short-term exposures |
WHO |
0,1 |
Permissible Exposure Limit (PEL-TWA) |
OSHA span> |
0,05 span> |
Time-weighed average concentration (TWA) |
NIOSH< /span> |
0,025< /span> |
Threshold Limit Value (TLV) |
ACGIH< /span> |
0,03 span> |
Recommended concentration after commercial cleaning |
ATSDR< /span> |
0,001< /span> |
Recommended inhalation zone limit in homes after spill |
ATSDR< /span> |
0,0018 |
Reference Exposure Level (REL), (1 hour) |
CalEPA |
0,0003 |
Reference Concentration (RfC) |
USEPA< /span> |
0,0002 |
Minimum Risk Level (MRL) |
ATSDR< /span> |
0,00006 |
Reference Exposure Level (REL), long term concentration |
Health Canada |
0,00003 |
Reference Exposure Level (REL), long term concentration |
CalEPA |
Yours truly,
Allan Astrup
Jensen
FORCE Technology, Br=F8ndby
Phone: +45 43 26 70 00
*************************************************************************
Technical Vice President
Secretariat for Metrology, Chemical analysis and Management Systems
Park All=E9 345
2605 Br=F8ndby
Denmark
Direct: +45 43 26 70 81
Mobile: +45 40 94 10 22
Fax: +45 43 26 70 11
e-mail:
www: www.forcetechnology.com
This email and any files transmitted with it may contain confidential
information intended for the addressee(s) only. The information is not
to be
surrendered or copied to unauthorised persons. If you have received
this communication in error, please notify us immediately by email at:
info**At_Symbol_Here**forcetechnology.com
*************************************************************************
From:
DCHAS-L Discussion List [mailto:DCHAS-L**At_Symbol_Here**list.uvm.edu] On Behalf Of Ben Ruekberg
Sent: 11. maj 2010
13:43
To:
DCHAS-L**At_Symbol_Here**LIST.UVM.EDU
Subject: Re: [DCHAS-L] 3
re: Hg
response
Not wishing to be disputatious concerning the hazards of mercury, nonetheless, I think before worrying about the saturation vapor pressure of mercury, I suspect that one should also consider the rate of evaporation of mercury as well. I don’t know what it is, but were it all that significant people would probably have to have been refilling McLoed gauges with some frequency. In fact, I don’t recall that ever being necessary, nor do I recall finding significant amounts of mercury in the Nitrogen traps of vacuum systems under normal circumstances. Given that most rooms have reasonable air exchange, I suspect that rooms seldom reach saturation.
To refer to the example of 5 mg of mercury reaching the saturation concentration of 15 mg m^-3, one would be dealing with a room with a volume of 1/3 m^3, an unusually small room. A 20’ X 20’ X 10’ room would hold (at saturation, with no air exchange) ~ 1.6 g of mercury, a mere drop, but if a drop of mercury evaporated at a significant rate an amount that might be noticeable.
What I am suggesting is that the rate of evaporation might be more important than the saturation vapor pressure and may reduce the hazard (at least for the short term) and that one might not need to be overly alarmed.
Thank you,
Ben
From:
DCHAS-L Discussion List [mailto:DCHAS-L**At_Symbol_Here**LIST.UVM.EDU] On Behalf Of List Moderator
Sent: Tuesday, May 11,
2010 7:16
AM
To:
DCHAS-L**At_Symbol_Here**LIST.UVM.EDU
Subject: Re: [DCHAS-L] 3
re: Hg
response
From: "Allan Astrup Jensen" <aaj**At_Symbol_Here**force.dk>
Date: May 11, 2010 5:26:29 AM EDT
Subject: RE: [DCHAS-L] 3 re: Hg response
< /font>
< /font>
Please, don’t underestimate the danger of mercury vapour!
Mercury vapour is dangerous, and it is difficult to clean up indoor spills completely. Even the 5 mg Hg from a crushed light bulb indoors can create dangerous air concentrations, as many publications have shown. The saturated air concentration at room temperature is about 15 mg Hg/m3. That concentration is 500 times higher than the TLV, and such exposures have resulted in serious intoxications.
Yours truly,
Allan Astrup Jensen
< /font>
Technical Vice President
Secretariat for Metrology, Chemical analysis and Management Systems
< /font>
FORCE Technology, Br=F8ndby
Park All=E9 345
2605 Br=F8ndby
< /font>
Phone: +45 43 26 70 00
Direct: +45 43 26 70 81
Fax: +45 43 26 70 11
e-mail: aaj**At_Symbol_Here**force.dk
< /font>
************************* ************************************************
This email and any files transmitted with it may contain confidential
information intended for the addressee(s) only. The information is not to be
surrendered or copied to unauthorised persons. If you have received
this communication in
error,
please notify us immediately by email at: info**At_Symbol_Here**forcetechnology.com
************************* ************************************************
< /font>
< /font>
< /font>
< /font>
< /font>
Previous post | Top of Page | Next post