Date: Fri, 25 Sep 2009 17:15:44 -0400
Reply-To: "Dr. Jay A. Young" <chemsafety**At_Symbol_Here**VERIZON.NET>
Sender: DCHAS-L Discussion List <DCHAS-L**At_Symbol_Here**LIST.UVM.EDU>
From: "Dr. Jay A. Young" <chemsafety**At_Symbol_Here**VERIZON.NET>
Subject: Re: Iodine corrosivity
Comments: To: List Moderator

Wayne,
 
And after the iodine gets through the zinc coating it reacts to make BEAUTIFUL FeI3 crystals.  Try it sometime, it is a lovely reaction, especially if you pass I2 vapor over hot iron filings in a closed system, of course.
 
The FeI3 crystals form and then fall like colored snow toward the bottom of the reaction space.
 
Jay Young
----- Original Message -----
From: List Moderator
To: DCHAS-L**At_Symbol_Here**LIST.UVM.EDU
Sent: Friday, September 25, 2009 11:08 AM
Subject: Re: [DCHAS-L] Iodine corrosivity

From: Wayne Wolsey <wolsey**At_Symbol_Here**macalester.edu>
Subject: Re: [DCHAS-L] Iodine corrosivity
Date: September 24, 2009 4:09:29 PM EDT

If the metal trap is galvanized iron, meaning zinc-coated, certainly zinc will react spontaneously with I2 in a redox reaction giving Zn2+ and iodide, I- .  The same thing can happen with aluminum, with similar chemistry.

Wayne Wolsey
Professor Emeritus
Macalester College
St. Paul, MN


===
From: Ernest Lippert <ernielippert**At_Symbol_Here**toast.net>
Subject: Re: [DCHAS-L] Iodine corrosivity
Date: September 24, 2009 5:39:12 PM EDT

Linda,
Based on the observed results, elemental iodine will corrode a metal trap. A knowledge of basic descriptive chemistry, as it was once taught, bears this out. There are a couple of things wrong here, not the least of which was an incorrect disposal method. A plumber should have been called to remove and clean the trap. His visit would be followed by proper disposal of the residue. If this couldn't have been done and as a last effort, the teacher perhaps should have known that iodine is much more soluble in a solution of potassium iodide than in water. On the other hand, is it preferable to have a leak with its obvious local contamination followed by proper disposal of the residues than it is to discharge a (significant) amount of iodine and KI into the sewer system?

Regards,
Ernest Lippert

===
From: Robert Weeks <rweeks**At_Symbol_Here**lanl.gov>
Subject: Re: [DCHAS-L] Iodine corrosivity
Date: September 25, 2009 10:57:28 AM EDT

Certainly a possibility. Might be interesting to perform  surogate experiments w/iodine crystals and pieces of pipe metal. Do the experiment w/iodine crystals, w/whatever else might have gone down this drain, and then w/iodine crystals plus whatever else might have gone down the drain.
Bob





Previous post   |  Top of Page   |   Next post



The content of this page reflects the personal opinion(s) of the author(s) only, not the American Chemical Society, ILPI, Safety Emporium, or any other party. Use of any information on this page is at the reader's own risk. Unauthorized reproduction of these materials is prohibited. Send questions/comments about the archive to secretary@dchas.org.
The maintenance and hosting of the DCHAS-L archive is provided through the generous support of Safety Emporium.