Date: Wed, 27 May 2009 13:41:01 -0700
Reply-To: Eric Clark <erclark**At_Symbol_Here**PH.LACOUNTY.GOV>
Sender: DCHAS-L Discussion List <DCHAS-L**At_Symbol_Here**LIST.UVM.EDU>
From: Eric Clark <erclark**At_Symbol_Here**PH.LACOUNTY.GOV>
Subject: Guanidine thiocyanate
In-Reply-To: <C3E98B533BBA314490DC0D1C18E02317095A4C72**At_Symbol_Here**pb01msx.wgipb.local>
aka [CAS 90229-46-2]
Hello All, 
Are there any special precautions regarding the disposal of guanidine 
thiocyanate solution?  If you use this compound, what is your disposal 
method?  From the MSDS it appears sewerable; but the MSDS data on the 
Incompatibility With Other Substances as Not Available.  A senior 
researcher mentioned that this compound produces toxic gas when it 
contacts bleach or other oxidizers - substances typically found in sewer 
lines of a microbiology lab - and that's what I need to check up on.  
We're talking about liter quantities **At_Symbol_Here** 50% - 60% solutions.  
Thanks, 
Eric

Eric Clark, MS, CCHO, CHMM  
Safety Officer, Los Angeles County Public Health Lab 

Previous post   |  Top of Page   |   Next post



The content of this page reflects the personal opinion(s) of the author(s) only, not the American Chemical Society, ILPI, Safety Emporium, or any other party. Use of any information on this page is at the reader's own risk. Unauthorized reproduction of these materials is prohibited. Send questions/comments about the archive to secretary@dchas.org.